Controlling an acroname USB hub

The acroname auxiliary offers commands to control an acroname usb hub. Ports can be switched individually and their current and voltage can be measured. It is also possible to retrieve and set the current limitation of each port.

Usage Examples

To use the auxiliary in your test scripts the auxiliary must be properly defined in the config yaml. Example:

auxiliaries:
    acro_aux:
      config:
        # Serial number to connect to. Example: "0x66F4859B"
        serial_number : null # null = auto detection.
      type: pykiso.lib.auxiliaries.acroname_auxiliary:AcronameAuxiliary

Below find a example for the usage in a test script. All available methods are shown there. For convenience units can be selected via a string. For current methods use ‘uA’, ‘mA’ or ‘A’. For voltage methods use ‘uV’, ‘mV’ or ‘V’. If not specified ‘V’ or ‘A’ will be used.

##########################################################################
# Copyright (c) 2010-2022 Robert Bosch GmbH
# This program and the accompanying materials are made available under the
# terms of the Eclipse Public License 2.0 which is available at
# http://www.eclipse.org/legal/epl-2.0.
#
# SPDX-License-Identifier: EPL-2.0
##########################################################################

"""
Acroname auxiliary test
***********************

:module: test_acroname

:synopsis: Example test that shows how to control the acroname usb.

.. currentmodule:: test_acroname

"""

import logging
import time

import pykiso
from pykiso.auxiliaries import acro_aux


@pykiso.define_test_parameters(suite_id=1, case_id=1, aux_list=[acro_aux])
class TestWithPowerSupply(pykiso.BasicTest):
    def setUp(self):
        """Hook method from unittest in order to execute code before test case run."""
        logging.info(
            f"--------------- SETUP: {self.test_suite_id}, {self.test_case_id} ---------------"
        )

    def test_run(self):
        logging.info(
            f"--------------- RUN: {self.test_suite_id}, {self.test_case_id} ---------------"
        )

        logging.info("Power off all usb port")

        for port_number in range(4):
            acro_aux.set_port_disable(port_number)

        time.sleep(2)

        logging.info("Power on all usb ports")

        for port_number in range(4):
            acro_aux.set_port_enable(port_number)

        time.sleep(2)

        logging.info("Set current limit on all usb ports to 1000 mA")

        for port_number in range(4):
            acro_aux.set_port_current_limit(port_number, 1000, "mA")

        logging.info("Take measurements on all usb ports")
        for port_number in range(4):
            voltage = acro_aux.get_port_voltage(port_number, "V")
            current = acro_aux.get_port_current(port_number, "mA")
            current_limit = acro_aux.get_port_current_limit(port_number, "mA")
            logging.info(
                f"Measured {voltage:.3f}V {current:.3f}mA "
                f"currentlimit {current_limit:.3f}mA on usb Port {port_number}"
            )

        logging.info("Set current limit on all usb ports to maximum -> 2500 mA")
        for port_number in range(4):
            current_limit = acro_aux.set_port_current_limit(port_number, 2500, "mA")

    def tearDown(self):
        """Hook method from unittest in order to execute code after test case run."""
        logging.info(